|
Note: Not all studies are available based
on copyrights of the original documents. Please
note the PARI Pharma copyright studies are
owned by PARI Pharma. Data may not be referenced in any
way including print and electronic formats
without the prior written consent of PARI Pharma.
[DDL 12-00 006]. Stangl, N. Luangkhot, J.
Jauernig, D. Häuser, F.-C. Lintz, R. Liening-
Ewert, D. Jahn, M. Keller, M. Knoch:
Estimating the Efficiency of a Vibrating
Membrane Nebuliser.
DDL XI, London, December 11-12, 2000;
Proceedings, pp. 207 - 210, (poster
presentation). |
 |
[DDL 12-00 005] Luangkhot, J. Jauernig, A.
Balcke, F.-C. Lintz, R. Liening-Ewert, R.
Stangl, M. Keller:
Characterisation of salbutamol solution
compared to budesonide suspensions consisting of
submicron and micrometer particles in the PARI
LC STAR® and a new PARI electronic Nebuliser
(e-Flow).
DDL XI, London, December 11-12, 2000;
Proceedings, pp. 14 - 17, (oral presentation).
M. Knoch, E. Sommer: Jet Nebulizer Design and
Function. Eur Respir Rev 2000; 10: 72,
183-186. |
 |
[AAPS 10-00 004] N. Luangkhot, J. Jauernig, A.
Balcke, D. Jahn, R. Liening-Ewert, R.
Stangl, F.-C. Lintz, M. Keller, M. Knoch:
Characterisation of salbutamol solution
compared to budesonide suspensions consisting of
submicron- and micrometer particles in the PARI
LC STAR® and a PARI Electronic Nebuliser
(e-Flow) Prototype.
AAPS Annual Meeting, Indianapolis, Oct. 29 -
Nov. 2, 2000, (poster presentation), No. 2117. |
 |
[RDD 05-00 003] R. Stangl, N. Luangkhot, R.
Liening-Ewert, D. Jahn:
Characterising the First Prototype of a
Vibrating Membrane Nebuliser.
RDD VII, Palm Harbor at Tarpon Springs
(Florida), May 14-18, 2000; Proceedings pp. 455
- 458, (poster presentation). |
 |
[RDD 05-00 002] W. H. DeHaan, E. Sommer:
The potential of infrared sensors for online
aerosol characterization.
RDD VII, Palm Harbor at Tarpon Springs
(Florida), May 14 - 18, 2000. Proceedings pp.
561 - 563. |
 |
T. Todisco, A. Eslami, S. Baglioni, T. Sposini,
C. Tascini, E. Sommer, M. Knoch:
Basis for Nebulized Antibiotics: Droplet
Characterization and In Vitro Antimicrobial
Activity Versus Staphylococcus aureus,
Escherichia coli, and Pseudomonas aeruginosa.
Journal of Aerosol Medicine 13 (1), 2000, pp.
11-16. |
 |
C. Winnips, M. Keller:
The role of pMDIs in pulmonary drug delivery.
Innovations in Pharmaceutical Technology 6,
2000, pp 70-75. |
 |
R. Stangl, N. Luangkhot, R. Liening-Ewert, D.
Jahn:
Charakterisierung des Funktionsmodells eines
neuartigen Verneblers.
In: G. Scheuch (Hrsg.): Aerosole in der
Inhalationstherapie IV. München-Deisenhofen
2000. Dustri-Verlag Dr. Karl Feistle. S. 96 –
97. |
 |
N. Luangkhot, D. Jahn, E. Sommer, M. Knoch:
Reduzierung der Behandlungsdauer und des
Füllvolumens in der Verneblertherapie unter
Verwendung einer unverdünnten
Salbutamol-Lösung. In: G. Scheuch (Hrsg.):
Aerosole in der Inhalationstherapie IV.
München-Deisenhofen 2000. Dustri-Verlag Dr. Karl
Feistle. S. 98 – 103. |
 |
|